It is helpful for reading symbols that are printed
out of specification.
Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since
enabling Large
Intercharacter Gap (over 3x) could cause a narrow margins (5x)
to be interpreted as an intercharacter gap.
Definition:
Instructs the scanner to read symbols with gaps
between characters exceeding three times the narrow element
width.
Serial Cmd:
<K471,status,start and stop match status,start and stop output
status,largeintercharacter gap,fixed symbol length status,symbol
length,check character type,check character output
status>