PreviousNext

Large Intercharacter Gap (Codabar)

Usage:

It is helpful for reading symbols that are printed out of specification.

Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since enabling Large Intercharacter Gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap.

Definition:

Instructs the scanner to read symbols with gaps between characters exceeding three times the narrow element width.

Serial Cmd:

<K471,status,start and stop match status,start and stop output status,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled


PreviousNext