Specifies the exact number of characters that the
scanner will recognize (this does not include start and stop and
check character characters). The scanner ignores any symbol not
having the specified length.
Serial Cmd:
<K471,status,start and stop match status,start and stop output
status,large intercharacter gap,fixed symbol length status,fixed
symbol length,check character type,check character output
status>
Default:
10
Options:
1 to 128
Note:
Fixed Symbol Length Status must be enabled for Symbol Length to take
effect.
Note: Because of symbology limitations, setting
Symbol Length to any
number less than four will produce undetermined results.