Daisy Chain Autoconfigure
For quick setup of a daisy chain configuration.
The command to Autoconfigure the daisy chain is sent to the primary scanner and the software responds in the following ways:
- Counts the number of secondary scanners in the daisy chain.
- Assigns an internal ID number (1...n) to each secondary scanner, where the first secondary scanner is number 1 (the primary scanner's ID being a 0).
- Propagates the communication settings and the relevant operating modes of the primary scanner to the ports of each secondary scanner.
- Resets each secondary scanner.
- Confirms that each secondary scanner has acquired the new settings.
When setting up a daisy chain operation, perform the following steps:
Important: All secondary scanners must be set to Serial Data Trigger Mode for Daisy Chain to function.
Before Autoconfigure, the primary scanner must be set to Serial (S):
After Autoconfigure, the primary scanner can be set to External Edge (E), but the other scanners must remain in Serial (S):
Important: If the scanner is Ethernet-enabled, first check to determine if RS-232 B is available. If it is available, set RS-232 B as the Source port in Array Communication Modes. Otherwise, set RS-232 A as the Source port. Port Routing for Symbol Data Output and Extra Symbol Information will be disabled on the Source port.