Sequence on No Read

Sequence on No Read is useful when the scanner needs to stay in sequence even if no decode occurs.

When Sequence on No Read is Enabled and Matchcode Type is set to Sequential, the scanner sequences the master symbol on every match or No Read. When disabled, it does not sequence on a No Read.

Consider the following decodes as an example of Sequence on No Read Enabled:

Master Symbol
Decoded Symbol
Master Symbol after Decode
001
001
002
002
002
003
003
No Read
004 (sequence on No Read)
004
004
005
005
No Read
006 (sequence on No Read)
006
No Read
007 (sequence on No Read)
007
007
008

Consider the following decodes as an example of Sequence on No Read Disabled:

Master Symbol
Decoded Symbol
Master Symbol after Decode
001
001
002
002
002
003
003
No Read
003 (not sequenced)
003
003
004
004
No Read
004 (not sequenced)
004
No Read
004 (not sequenced)
004
004
005