PreviousNext

Read Cycle

Trigger Mode / Trigger Filter Duration
<K200,trigger mode,leading edge trigger filter duration,trailing edge trigger filter duration>
Serial Trigger Character
<K201,serial trigger character>
External Trigger State
<K202,external trigger state>
End of Read Cycle
<K220,mode,read cycle timeout>
Decodes Before Output
<K221,mode,number before output>
Multisymbol
<K222,number of symbols,multisymbol separator>
Serial Trigger Start Character
<K229,start character>
Serial Trigger Stop Character
<K230,stop character>
Processing Timeout
<K245,processing timeout>
Scan Speed
<K500,scan speed>
Maximum Element
<K502,maximum element>
Automatic Gain Control
<K504,gain level,AGC sampling mode,AGC minimum,AGC maximum>
Symbol Detect Status / Transition Counter
<K505,symbol detect status,transition counter>
Raster Framing
<K506,status,top offset,bottom offset,sweep rate,read cycle on/off>
Scan Width Enhance
<K511,status>
AGC Tracking
<K520,tracking>
Laser Setup
<K700,laser on/off,laser framing status,laser on position,laser off position,laser power>

Trigger Mode / Filter Duration
Trigger Mode
Serial Cmd:
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default:
0 = Continuous Read
Options:
0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and Edge
Leading Edge Trigger Filter
Serial Cmd:
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default:
313 (~10 ms)
Options:
1 to 65535 (x 32.0 µs)
Trailing Edge Trigger Filter
Serial Cmd:
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default:
313 (~10 ms)
Options:
1 to 65535 (x 32.0 µs)

PreviousNext