PreviousNext
Maximum Element
Serial Cmd:
<K502,maximum element>
Default:
400 (x 0.01% of scan)
Options:
50 to 5000
Automatic Gain Control
AGC Level
Serial Cmd:
<K504,AGC level,AGC mode,minimum gain,maximum gain>
Default:
40 (QX-870 model-dependent - see Microscan Product Pricing Catalog)
Options:
0 to 255
AGC Mode
Serial Cmd:
<K504,AGC level,AGC mode,minimum gain,maximum gain>
Default:
2 = Continuous
Options:
0 = Disabled
1 = Leading Edge
2 = Continuous
Minimum Gain
Serial Cmd:
<K504,AGC level,AGC mode,minimum gain,maximum gain>
Default:
0 (QX-870 model-dependent - see Microscan Product Pricing Catalog)
Options:
0 to 255
Maximum Gain
Serial Cmd:
<K504,AGC level,AGC mode,minimum gain,maximum gain>
Default:
255 (QX-870 model-dependent - see Microscan Product Pricing Catalog)
Options:
0 to 255

PreviousNext