Symbol Data Output
Symbol Data Output Status
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output status> Default: 3 = Good Read Options: 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read
When to Output Symbol Data
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output status> Default: 0 = As Soon As Possible Options: 0 = ASAP 1 = End of Read Cycle
Symbology ID Output Status
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output status> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID