PreviousNext
Symbol Data Output
Symbol Data Output Status
Serial Cmd:
<K705,symbol data output status,when to output,symbology i.d. output status>
Default:
3 = Good Read
Options:
0 = Disabled
1 = Match
2 = Mismatch
 
3 = Good Read
When to Output Symbol Data
Serial Cmd:
<K705,symbol data output status,when to output,symbology i.d. output status>
Default:
0 = As Soon As Possible
Options:
0 = ASAP
1 = End of Read Cycle
Symbology ID Output Status
Serial Cmd:
<K705,symbol data output status,when to output,symbology i.d. output status>
Default:
0 = Disabled
Options:
0 = Disabled
1 = Enabled (AIM-Defined ID)
2 = Readable ID

PreviousNext