Output 1 Parameters
Output On
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
Mismatch or No Read
Options:
0 = Mismatch or No Read
1 = Match or Good Read
2 = Mismatch
3 = No Read
4 = Trend Analysis
5 = Validation
6 = Diagnostic Warning
7 = In Read Cycle
8 = Read Cycle Data Valid
Output State
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
0 = Normally Open
Options:
0 = Normally Open
1 = Normally Closed
Pulse Width
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
50 (50 ms)
Options:
1 to 65535 (in 1 ms increments)
Output Mode
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
0 = Pulse
Options:
0 = Pulse
 
1 = Latch Mode 1 (Unlatch Input 1 Pin)
 
2 = Latch Mode 2 (Unlatch Opposite Condition)
 
3 = Latch Mode 3 (Unlatch Re-Enter Read Cycle)