PreviousNext
Output Format Status
Serial Cmd:
<K743, output format status>
Default:
0 = Disabled
Options:
0 = Disabled
1 = Enabled
Output Filter Configuration
Filter Number
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Options:
1 to 10
Symbology Type
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Default:
0
Options:
0 = Any type
1 = Interleaved 2 of 5
2 = Code 39
3 = Code 128
4 = Codabar
5 = UPC
6 = PDF417
7 = EAN 128
8 = Code 93
9 = Pharmacode
10 = GS1 DataBar (RSS)
11 = MicroPDF417
12 = Composite
Length
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Default:
0
Options:
0 to 128
Wildcard
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Default:
* = (0x2A)
Options:
Any ASCII input in the form of a pair of hex characters
Placeholder
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Default:
? = (0x3F)
Options:
Any ASCII input in the form of a pair of hex characters
Data
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Default:
NULL (0x00)
Options:
Any ASCII input in the form of a pair of hex characters
Decode Direction
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Default:
0 = Any Direction
Options:
0 = Any Direction
 
1 = Forward
 
2 = Reverse
Database Index
Serial Cmd:
<K744, filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index>
Default:
0 (any index)
Options:
0 to 10

PreviousNext