NET and MOD LED Indicators

MOD (Module)

Indicator State
Summary
Requirement
Microscan Implementation
Steady OFF
No power
If no power is supplied to the device, the module status indicator will be steady OFF.
Per requirement
Steady GREEN
Device operational
If the device is operating correctly, the module status indicator will be steady GREEN.
Per requirement
Flashing GREEN
Standby
If the device has not been configured, the module status indicator will be flashing GREEN.
When operating with default parameters. Default status is updated at reset.
Flashing RED
Minor fault
If the device has detected a recoverable minor fault, the module status indicator will be flashing RED.
1. Temperature warning.

2. Scan sync missing. This may occur briefly when the scan motor starts and stops.

Steady RED
Major fault
If the device has detected a non-recoverable minor fault, the module status indicator will be steady RED.
1. Laser current warning.

2. Safe Mode: Basic comm. only. Scanning system is non-functional.

Flashing GREEN / RED
Self-test
While the device is performing its power-up testing, the module status indicator will be flashing GREEN / RED.
Per requirement, but unlikely to be seen.