Indicator State
|
Summary
|
Requirement
|
Microscan Implementation
|
Steady OFF
|
No power
|
If no power is supplied to the device, the
module status indicator will be steady OFF.
|
Per requirement
|
Steady GREEN
|
Device operational
|
If the device is operating correctly, the
module status indicator will be steady GREEN.
|
Per requirement
|
Flashing GREEN
|
Standby
|
If the device has not been configured, the
module status indicator will be flashing GREEN.
|
When operating with default parameters.
Default status is updated at reset.
|
Flashing RED
|
Minor fault
|
If the device has detected a recoverable
minor fault, the module status indicator will be flashing RED.
|
1. Temperature warning.
2. Scan sync missing. This may occur briefly when
the scan motor starts and stops.
|
Steady RED
|
Major fault
|
If the device has detected a non-recoverable
minor fault, the module status indicator will be steady RED.
|
1. Laser current warning.
2. Safe Mode: Basic comm. only. Scanning system is
non-functional.
|
Flashing GREEN /
RED
|
Self-test
|
While the device is performing its power-up
testing, the module status indicator will be flashing GREEN / RED.
|
Per requirement, but unlikely to be
seen.
|