PreviousNext

Assembly Instance 100 (Input)

This assembly supports implicit messaging and represents 20 DINTs of data. Typically, you connect to this instance by configuring the Generic Ethernet Module according to the instructions listed in the section "Setting Up The PLC Program". Because the connectivity is implicit, this data is refreshed at regular intervals by the network.

DINT

Meaning

0
32 Bits of Camera Virtual IO
1
User defined tag value
2
Camera Status Register
3
Last Error
4...19
64 bytes of user data


PreviousNext