DINT 2: Camera Status Register
BIT
Meaning
0 Online: 0=offline (booting, loading job), 1=online 1 Run mode: 0=stopped, 1=running 2 Command Complete 3 Command Succeeded 4...31 Reserved
Commands sent to the Control Register are ignored when the camera is offline; the camera must be online before sending a Start trigger.