The following read cycle conditions are required for USB MINI Hawk:
Serial Cmd: <K200,read mode> Default: Continuous Options: 0 = Continuous Mode 1 = Coninuous Read 1 Output Mode 2 = Level Mode 3 = Edge Mode 4 = Serial Mode 5 = Serial and Edge Mode
Important:
- To use Level Mode, you must enable Undelimited Start Trigger Character <K229> and Undelimited End Trigger Character <K230>.
- To use Edge Mode, you must enable and use the Undelimited Start Trigger Character <K229>.
- To use Serial Mode, you must use the Delimited Trigger defined by <K201>, or enable and use the Undelimited Start Trigger Character <K229>.