Read Cycle Serial Commands

Trigger Mode/Filter Duration
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Serial Trigger Character
<K201,serial trigger character>
External Trigger State
<K202,external trigger state>
End of Read Cycle
<K220,end of read cycle,read cycle timeout>
Minimum Good Reads
<K221,minimum good reads>
Multisymbol
<K222,number of symbols,multisymbol separator>
Start Trigger Character
<K229,start character>
Stop Trigger Character
<K230,stop character>
Capture Mode
<K241,capture mode,number of captures,rapid capture mode>
Capture Timing
<K242,time before first capture,time between first and second captures,,,,,,,,time between seventh and eighth captures>
Image Storage
<K244,image storage type,image store mode>
IP Timeout
<K245,image processing timeout>


PreviousNext