In Rapid Capture Mode, one or multiple captures (as many
as 32) can be taken at an interval specified by the
time-between-captures parameter. In this mode, the only limiting
time factor is integration and transfer timing.
Serial Cmd:
<K241,capture mode,number of captures,rapid capture mode>
Default:
Timed Capture
Options:
0 = Timed Capture
1 = Triggered Capture
Timed Capture
Usage:
Timed Rapid Capture is useful in fast-moving
applications in which symbols are only in the field of view for a
short time and precise timing is required.
Definition:
In Timed Rapid Capture, decoding occurs independent of and
simultaneous with capturing, thus allowing precise timing or no
delay at all between captures.
Also, consecutive captures are regarded as
the same symbol if the output data is the same.