Code 93 is a variable-length, continuous
symbology employing four element widths. Each Code 93 character has
nine modules that may be either black or white. Each character
contains three bars and three spaces.
Serial Cmd:
<K475,status,fixed
symbol length status,symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length Status (Code 93)
Definition:
When disabled, the imager will accept any
Code 93 symbol provided is doesn't exceed the system's maximum
capabilities.
When enabled, the imager will reject any
Code 93 symbol that doesn't match the fixed symbol length.
Serial Cmd:
<K475,status,fixed symbol length status,symbol
length>