Trigger Filter Duration

Usage:
Trigger Filter Duration allows the Imager to disregard false trigger events.
Definition:
When Trigger Mode is set to either External Edge or External Level, the read cycle's active state must be delayed until the specified filter duration has elapsed. The Imager will trigger at the end of that duration.
Serial Cmd:
<K200,trigger mode,trigger filter duration>
Default:
313 (x 32 µs = 10.24 mS)
Options:
1 to 65535 (corresponding with 32 µs  to 2.097 seconds in 32 µs steps)

Note: If Trigger Mode is set to External Edge, the Imager will trigger only after the active state has been delayed for the specified filter duration.

Note: If Trigger Mode is set to External Level, the Imager will trigger once the active state has been delayed for the specified filter duration after the appearance of an object's active edge.

In addition, the active state must be delayed for the specified filter duration after the disappearance of the object's falling edge for the trigger to be rendered inactive.