PreviousNext

Number of Captures

Usage:
Used to increase the opportunities for good reads and to "extend" the field of view in dynamic applications.
Definition:
Sets the total number of captures that are processed during a read cycle in Rapid Capture Mode when Switching Mode is set to Number of Captures.
Serial Cmd:
<K241,capture mode,number of captures,rapid capture mode>
Default:
1
 
Options:
1 to 32

Note: The range of maximum number of captures is dynamic. This range is dependent on the maximum image size in the system. A full-size image (640 x 480) reduces the maximum number of images to 6. The smaller the image size, the greater the maximum number of captures. Once the image size is reduced to small enough dimensions, the maximum number of captures will be capped at 32.

If a user enters a maximum capture value greater than that allowed, the value will be limited to the number of system images. This command also affects the number of stored images allowed in the system. If the maximum number of captures is selected, the number of stored images allowed will be 0.