Check Digit Output Status (Code 39)

Usage:
Check Digit Output Status, added to the symbol, provides additional data security.
Definition:
When enabled, the check digit character is read and compared along with the symbol data. When disabled, symbol data is sent without the check digit.
Note: With Check Digit Output Status and an External or Serial trigger option enabled, an invalid check digit calculation will cause a No Read message to be transmitted at the end of the read cycle.
Serial Cmd:
<K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
 


PreviousNext