Range Mode Status (Interleaved 2 of 5)

Usage:
Useful in applications where I 2/5 symbols of a specific length are required.
Definition:
When Range Mode is disabled, the Imager checks the value of the symbol length against the values set in Symbol Length # 1 and Symbol Length # 2. If the symbol length does not match either of the preset values, then it is rejected as invalid.
When Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2 are combined to form a range of valid symbol lengths. Any symbol length that does not fall into this range is rejected as an invalid symbol. Either of the preset symbol length values in the Symbol Length # 1 and Symbol Length # 2 fields can form the start or end of the range.
Serial Cmd:
<K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar status,range mode status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
 