Definition:
|
When this field is disabled and a check
digit calculation is enabled, the Imager will strip the verified
check digit from the symbol data output. This condition must be
accounted for if a fixed length is also being used.
When enabled, the Imager will output the
check character as part of the symbol data. This condition must be
accounted for if a fixed length is also being used.
|
Serial Cmd:
|
<K471,status,start/stop match,start/stop output,large
intercharacter gap,fixed symbol length status,symbol length,check
digit type,check digit output>
|