PreviousNext

Configuring EZ Trax Output by Serial Command

Usage:
Useful for when you want to configure EZ Trax output using serial commands instead of the EZ Trax graphic interface.
Definition:
When EZ Trax output is enabled, the Imager will attempt to output all enabled EZ Trax options. EZ Trax will not function unless enabled.
Serial Cmd:
<K757,status,comm port,image mode,image format,jpeg quality,object info output, grade output>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled

Comm Port

Definition:
Selects the communication port that will be used to transfer image files.
Serial Cmd:
<K757,status,comm port,image mode,image format,jpeg quality,object info output, grade output>
Default:
Host
Options:
0 = Host
1 = Aux
2 = USB

Host Port

Sends output using the current Host Port.

Aux Port

Sends output using the Auxiliary Port.

USB

Sends output using a USB connection.


PreviousNext