Match Start Position

Usage:
Match Start Position is useful in defining specific portions of a symbol for comparison. For example, if a symbol contains a part number, manufacturing date, and lot code info, but you are only interested in the part number information, you can set the Imager to sort only the part number and ignore the other characters.
Definition:
Match Start Position determines the portions of symbols that will be matched by defining the first character in the symbol (from left to right) that will be compared with those of the master symbol, when Matchcode Type is set to Enabled or Sequential.
Function:
For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch>
Default:
0
Options:
0 to 3000
   

Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.