PreviousNext

Sequence on No Read

Usage:
Sequence on No Read is useful when the Imager needs to stay in sequence even if no decode occurs.
Definition:
When Sequence on No Read is Enabled and Matchcode is set to Sequential, the Imager sequences the master symbol on every match or No Read. When disabled, it does not sequence on a No Read.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch>
Default:
Enabled
Options:
0 = Disabled
 
1 = Enabled

As an example of Sequence on No Read Enabled, consider the following decodes:

Master Symbol
Decoded Symbol
Master Symbol after Decode
001
001
002
002
002
003
003
No Read
004 (sequenced on No Read)
004
004
005
005
No Read
006 (sequenced on No Read)
006
No Read
007 (sequenced on No Read)
007
007
008

As an example of Sequence on No Read Disabled, consider the following series of decodes:

Master Symbol
Decoded Symbol
Master Symbol after Decode
001
001
002
002
002
003
003
No Read
003 (not sequenced)
003
003
004
004
No Read
004 (not sequenced)
004
No Read
004 (not sequenced)
004
004
005