PreviousNext

New Master Pin

Definition:
If Matchcode and New Master Pin are enabled and the new master pin is momentarily connected to ground (must be held low for a minimum of 10 mS) master symbol information will be loaded into the database based on the next read cycle that achieves a Good Read, starting with Index 1. The Master Symbol Database will be loaded with all symbols decoded in the read cycle as long as it does not exceed the Number of Master Symbols parameter.
Serial Cmd:
<K225,status>
Default:
Disabled
Options:
0 = Disabled
 
1 = Enabled

New Master Load Status

Definition:
The new master status responds with the number of the next master position to be loaded, where 0 represents "idle" or "no master to be loaded."
Example: If the user has the Number of Master Symbols set to 1, and then either sends a <G> or toggles an active New Master Pin, the state will be 1, and prior to reading and effectively loading position 1, the response to <NEWM> would be <NEWM/1>. Once a symbol has been read and loaded, the status will be cleared: <NEWM/0>.
Serial Cmd:
<NEWM>