PreviousNext

Read Next Symbol as Master Symbol

Definition:
After you've set the size in the database, you can order the Imager to read the next symbol as the master symbol for any given master symbol number.
Serial Cmd:
<Gmaster symbol number>
To store the next symbol decoded as master symbol # 1, send:
<G> or <G1>.
To store the next symbol decoded as the master symbol for any other master symbol database number, send:
<Gmaster symbol number [1-10]>.
For example, <G5> will cause the next symbol read to be entered as master symbol # 5.
ESP:
In the Master Database tab under the Output Format menu,
  • Select the master symbol index number in which you want to store the symbol data.
  • Click the Read Symbol into Selected Index button.
Caution: If you've selected an index which already has existing data, that data will be copied over by new decoded data when you use this command.


PreviousNext