PreviousNext

Delete Master Symbol Data

Definition:
You can directly delete the master symbol data by serial command or by ESP.
ESP:
  • Click the Utilities button to access the master symbol.
  • Click the Master Database tab and double-click the symbol number you want to delete.
  • Delete text and click OK.
Serial Cmd:
<K231,master symbol number,>
To delete a master symbol, enter the database number and a comma, but leave the data field empty. For example, to delete master symbol # 5, send the following: <K231,5,>. The command is entered with a blank master symbol data field, which tells the Imager to delete the selected master symbol from the database.


PreviousNext