Microscan Default Parameters
Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults
Microscan default parameters can be recalled (loaded into current settings) with <Ard> command or recalled and saved for power-on with the <Zrd> command.
Hardware Default
If a software default and reset is not possible, it may be necessary to reset the reader by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command.
Important: For this reset to occur, this command must be executed within 60 seconds of a power-on or a reset.
Caution: Be certain that the correct pins are located. Connecting the wrong pins could cause serious damage to the unit.
Default on Power-On
You can also use the EZ button to default the reader by holding it down while applying power to the reader, provided that this feature is enabled.
![]() ![]() |