PreviousNext

Data

Definition:

This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index.

Examples:

  • Filter data = "123*". This will match data strings of "123", "123456", and "123ABC", but not "12".
  • Filter data = "123*AB?C". This will be interpreted as "123*".
  • Filter data = "123?". This will match "1234" and "123A", but not "123", "12345", or "1234C".
  • Filter data = "123?A". This will match "1234A" and "123BA", but not "123", "1234C", or "1234ABCD".
  • Filter data = "123?A?". This will match "1234AB" and "123BAT", but not "1234A" or "123BATS".
  • Filter data = "12??*". This will match "1234", "123456", and "123ABC", but not "12" or "123".
  • Filter data = "123?A*". This will match "1234A", "123BA", and "123BATS", but not "1234" or "1234C".
Serial Cmd:

<K744, filter number,symbology type,length,wildcard,placeholder,data, unused,database index>

Default:

00 (NUL)

Options:

Any ASCII input in the form of a pair of hex characters.

Maximum length: 63 bytes defined.

Data [0] = NUL represents string matching disabled.

Important: The ASCII characters <, >, and , can only be entered as hex pairs:

For <: <K744h,,,,,,3C>

For >: <K744h,,,,,,3E>

For , : <K744h,,,,,,2C>

See ASCII Character Entry Modifier for a detailed explanation of how to enter ASCII characters as hex values.