PreviousNext

Leading Edge Trigger Filter

Usage:
Used to ignore spurious triggers when Trigger Mode is set to External Edge or External Level.
Definition:
To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the imager will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the leading edge is filtered such that on an active edge, the state must be held interrupted for the trigger filter duration before a trigger will occur.
Serial Cmd:
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default:
31 (1 ms)
Options:
1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)


PreviousNext