Fixed Symbol Length helps prevent truncations and
increases data integrity by ensuring that only one symbol length
will be accepted.
Definition:
This specifies the exact number of
characters that the imager will recognize (this does not include
start, stop, and check character characters). The imager ignores
any symbol not having the specified length.
Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol
length,EAN 128 status,output format,application record separator
status,application record separator character,application record
brackets,application record padding>