Minimum Number of Bars (Pharmacode) Definition: Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid. Note: When Q-Mode is enabled, the minimum allowed bar count is 4. Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Default: 2 Options: 1 to 16 4 to 16 (Q-Mode)