Read Duration Output
Usage:
|
Useful in evaluating actual read cycle timing results,
especially when initially setting up an application to determine
maximum line speed (obtainable based on spacing between
symbols.)
|
Definition:
|
When enabled the duration of the read cycle
(in milliseconds) is appended to the symbol data.
The read duration is the time from the
beginning of the read cycle until data is output.
|
Read Duration Output Mode
Serial Cmd:
|
<K706,status,separator>
|
Default:
|
Disabled
|
Options:
|
0 = Disabled
|
1 = Enabled
|
Important: To measure the entire read
cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle.
This output can measure over 49 days' worth of
duration; if exceeded, the "OVERFLOW" message will be output in
place of the duration.