When set to this mode, and when the appropriate output is
set to output on trend analysis, the imager will function in a
Decodes per Trigger
mode during the read
cycle and the trend analysis operation. Output will be activated
based on whether or not the symbol decode count at the end of the
read cycle crosses the decodes per trigger threshold.
Note: Although this
setup causes the imager to function in a Decodes per Trigger mode, the
decode count will only be appended to the symbol data if the status
of the Decodes per
Trigger command is enabled.
|