Usage:
|
Match Start Position is useful in defining specific
portions of a symbol for comparison. For example, if a symbol
contains a part number, manufacturing date, and lot code info, but
you are only interested in the part number information, you can set
the imager to sort only the part number and ignore the other
characters.
|
Definition:
|
Match Start Position determines the portions of symbols
that will be matched by defining the first character in the symbol
(from left to right) that will be compared with those of the master
symbol, when Matchcode
Type is set to Enabled or Sequential.
|
Function:
|
For example, if Match Start Position is set to 3, the first 2 characters
read in the symbol will be ignored and only the 3rd and subsequent
characters to the right will be compared, up to the number of
characters specified by Match Length.
|
Serial Cmd:
|
<K223,matchcode type,sequential matching,match start position,
match length,wild card character,sequence on No Read,sequence on
mismatch>
|
Default:
|
0
|
Options:
|
0 to 3000
|