PreviousNext

Adaptive Contrast Percent

Definition:
The percentage value that sets the adaptive threshold map. Useful for underprinted or overprinted symbols.
For example, if a value of 110 is entered, the adaptive threshold will be 110% of the original values.
Serial Cmd:
<K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent>
Default:
100
Options:
1 to 200


PreviousNext