Fast Linear Mode (FLM) Direction
Definition:
|
This mode assumes that the whole image is
the candidate, and reads the image either horizontally or
vertically. When the number of symbols in the field of view
<K518> is set to 2, Fast Linear Mode will try to
locate the candidates first and then decode. The candidate symbols
cannot be side-by-side-they must be parallel.
|
Usage:
|
<K527,IP
Mode,FLM direction>
|
Default:
|
Auto
|
Options:
|
0 = Auto
|
|
1 = Horizontal
|
|
2 = Vertical
|
Auto
The imager tries to read both horizontally and
vertically. It decides which direction to process first based on
Window of Interest dimensions. For example, if the WOI height is
greater than its width, the imager attempts to read vertically
first, and if there is no decode, then it attempts to read
horizontally.