Definition:
|
This field allows the user to configure the
database to enable specific symbologies for selected database
indexes. Symbology-specific parameters must be configured with the
appropriate symbology command.
For example, if fixed length Code 128 is
required, it must first be set up with the Code 128 command:
<K474>.
To select a particular symbology, add the
number value associated with that symbology type.
Examples:
If Data Matrix and Code 39 are required, the
paramater would be: 2 + 16 = 18.
If I 2/5, BC412, and DataBar Limited (RSS
Limited) are required, the parameter would be: 128 + 2048 + 16384 =
18560.
|
Serial Cmd:
|
<K255,index,shutter speed,gain,pixel binning,row pointer,column
pointer,row depth,column width,threshold mode,fixed threshold
value,processing mode, narrow margins,background
color,symbology>
|