PreviousNext

Sequence on Mismatch

Note: Matchcode Type must be set to Sequential for this command to function.

Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. When set to Enabled, the master symbol sequences on every decode, match, or mismatch.

Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur. When set to Disabled, the master symbol will not sequence whenever consecutive mismatches occur.

The imager will sequence the master to one more or one less than the decoded symbol.

Consider the following decodes as an example of Sequence on Mismatch Enabled:

Master Symbol
Decoded Symbol
Master Symbol after Decode
001
001
002
002
002
003
003
abc
004 (sequence on mismatch)
004
004
005
005
def
006 (sequence on mismatch)
006
ghi
007 (sequence on mismatch)
007
007
008

Consider the following decodes as an example of Sequence on Mismatch Disabled:

Master Symbol
Decoded Symbol
Master Symbol after Decode
001
001
002
002
002
003
003
abc
004 (sequenced because of previous match)
004
004
005
005
def
006 (sequenced because of previous match)
006
ghi
006 (not sequenced)
006
006
007


PreviousNext