PreviousNext

Built-In Strobe Output

The Visionscape GigE cameras incorporate an output for a strobe signal that is coordinated with image acquisition.

Figure 2-7 shows the output opto wiring (Strobe ) for isolated outputs.

FIGURE 2-7. Output Opto Wiring (Flash) for Isolated Inputs

Flash Output Signal Response:

Logic Low: 0 to 4.5 Vdc

Logic High: 5 to 30 Vdc. (24Vdc @ 16ma recommended)

Flash Delay: 2usec (typical)

Note: Flash Off Time: ~ 40?sec.