Built-In Strobe Output
The Visionscape GigE cameras incorporate an output for a strobe signal that is coordinated with image acquisition.
Figure 2-7 shows the output opto wiring (Strobe ) for isolated outputs.
FIGURE 2-7. Output Opto Wiring (Flash) for Isolated Inputs
Flash Output Signal Response:
Logic Low: 0 to 4.5 Vdc
Logic High: 5 to 30 Vdc. (24Vdc @ 16ma recommended)
Flash Delay: 2usec (typical)
Note: Flash Off Time: ~ 40?sec.