PreviousNext

Calibration Progress Output Examples (Terminal)

Search Pass

The purpose of Search Pass is to decode a symbol in as few configurations as possible during calibration. This process is designed to quickly identify symbology type, and any image processing parameters that are already calibrated.

Running Search Pass

Prog

Rating

Decode

Quality

Shutter

Gain

Locate

12

0

0

0

250

0

0

14

0

0

0

250

9

0

16

0

0

0

250

18

0

18

2174

1

72

250

27

24

Medium Pass

The theory behind Medium Pass is to develop a readable range from which to dial in a decoded symbol.

Running Medium Pass

Prog

Rating

Decode

Quality

Shutter

Gain

Locate

51

4216

2

8

250

0

5

53

8436

4

20

250

4

4

55

6336

3

24

250

8

4

57

8448

4

32

250

12

4

59

8456

4

40

250

16

5

61

8464

4

48

250

20

4

63

8472

4

56

250

24

5

65

8488

4

72

250

28

5

67

8504

4

88

250

32

5

69

8512

4

96

250

36

5

71

8528

4

112

250

40

6

73

8584

4

168

250

44

5

75

8644

4

228

250

48

5

             

Rating List (Best):

Rating = 8606; Shutter = 250; Gain = 48

Rating = 8581; Shutter = 250; Gain = 44

Rating = 8553; Shutter = 250; Gain = 40

Rating = 8527; Shutter = 250; Gain = 36

Rating = 8505; Shutter = 250; Gain = 32

Rating = 8488; Shutter = 250; Gain = 28

Rating = 8476; Shutter = 250; Gain = 24

Fine-Tune Pass

The theory behind Fine-Tune Pass is to dial in a decoded symbol based on the range supplied by the Medium Pass.

Running Fine Tune Pass

Prog

Rating

Decode

Quality

Shutter

Gain

Locate

77

6416

3

104

250

38

7

79

6424

3

112

250

39

6

81

6424

3

112

250

40

6

84

6432

3

120

250

41

6

86

6448

3

136

250

42

5

88

6464

3

152

250

43

5

90

6476

3

164

250

44

5

93

6488

3

176

250

45

5

95

6506

3

194

250

46

6

97

6524

3

212

250

47

5

100

6538

3

226

250

48

6

Rating List (Best):

Rating = 6527; Shutter = 250; Gain = 48

Rating = 6517; Shutter = 250; Gain = 47

Rating = 6505; Shutter = 250; Gain = 46

Rating = 6491; Shutter = 250; Gain = 45

Rating = 6476; Shutter = 250; Gain = 44

Rating = 6462; Shutter = 250; Gain = 43

Rating = 6449; Shutter = 250; Gain = 42

Calibration PASSED.


PreviousNext