Additional Notes about Calibration
The following conditions apply to the Imager's
calibration process. Some of these items are noted at various
points throughout this section, or in other sections of the
Imager's documentation.
- The Mirrored Image parameter <K514> is not part of the calibration
process.
- IP Mode <K527>
will not be altered during calibration.
- Threshold Mode <K512> will be set to Adaptive during calibration.
At the end of a successful calibration, Threshold Mode will remain
set to Adaptive
regardless of its previous setting. Otherwise, the value will
revert to its original state.
- If Symbol Type is enabled for calibration
(Autodiscriminate),
then Interleaved 2 of 5 Range Mode Status (Interleaved 2 of 5) <K472> will be enabled. This allows
variable-length Interleaved 2 of 5 symbols to be decoded. If an
Interleaved 2 of 5 symbol is decoded during calibration, then
symbol length # 1 will be set to the decoded symbol length at the
end of calibration. Otherwise, the symbol lengths will be restored
to their original configurations.
- The symbol size, dimension, and orientation parameters of the
No Symbol Message
and Bad Symbol
Message, and 2D
Symbology Qualification command <K718> will be updated if calibration is
completed successfully.
- All symbol types that were enabled before calibration will
still be enabled after calibration. For example, if Data Matrix ECC
200 was enabled before calibration, and the calibration routine was
performed on a Code 128 symbol, then after calibration is completed
both Data Matrix ECC 200 and Code 128 will be enabled.
- The calibration process does not modify the global Composite status <K453>.
The global Composite status must be configured properly before
calibration.
- If the user requires calibration of a stacked symbology <K482>, <K483>, or
<K484>, that symbology must be enabled
and configured appropriately before calibration.
- The Search Pass process will
use the configurable Window of Interest for image captures.
However, when the search process is completed, the WOI will be
reduced to include only the symbol of interest and some additional
boundary area.