PreviousNext

GS1 DataBar

DataBar Expanded

Usage:
Used to encode primary and supplementary data in retail point-of-sale and other applications.
Definition:
DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters.
Serial Cmd:
<K484,status,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled (non-stacked)
2 = Enabled (stacked and non-stacked)

Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and non-stacked).


PreviousNext