PreviousNext

Connect the System

There are a number of different ways to connect a reader, the MS-Connect 210, and a host.

The 19-pin reader connector; the Micro-Change connectors for the power supply, optional Ethernet, and optional object detector; and three CGBs are located at the back of the unit.

Connecting a 10-28 Volt Reader to the MS-Connect 210

If you are using an MS-9, MS-820, MS-860, MS-890, Quadrus EZ, or Quadrus Verifier:

  • Attach the 19-pin to 25-pin Reader Cable to the MS-Connect 210 via the 19-pin reader connector, shown in the illustration above.

Important: The MS-9 requires a 19-pin to 15-pin Reader Cable.

The MS-820 requires a 19-pin to 15-pin Reader Cable, P/N 61-000121-01.

  • Tighten the cable housing at the 19-pin reader connector on the back of the MS-Connect 210 unit.
  • Attach cabling inside the wiring box.
  • Attach an Object Detector (optional) to the MS-Connect 210 via the trigger Micro-Change connector, shown in the illustration above.
  • Attach the Power Supply to the MS-Connect 210 via the power Micro-Change connector, shown in the illustration above.


PreviousNext