PreviousNext

Read Cycle Setup

Setting up read cycle and triggering parameters will involve a series of decisions based on your particular application, as follows:

  • Select the number of symbols to be read in a single cycle. The Quadrus MINI Velocity can read multiple symbols in a single image frame.
  • Decide on the trigger type to be used: if serial, choose a serial character; if external, choose either Level or Edge.
  • Designate how the read cycle should end (Timeout, New Trigger, Last Frame).
  • Select Capture Mode, Continuous Mode, or Rapid Mode.
  • Select Number of Captures (if in Rapid Capture Mode).
  • Set the Time Before First Capture and Time Between Captures, if any.

Note: The Quadrus MINI Velocity's camera captures images at a rate of 60 per second (based on a full-size 752 x 480 image). The frame rate increases as the frame size decreases.

Note: If you need to set up your Quadrus MINI Velocity for use with EZ Trax software, see Setting Up the Imager for EZ Trax.


PreviousNext