PreviousNext

Rapid Capture Mode

Definition:
In Rapid Capture Mode, one or multiple captures (as many as 64) can be taken at an interval specified by the time-between-captures parameter. In this mode, the only limiting time factor is integration and transfer timing.
Serial Cmd:
<K241,capture mode,number of captures,rapid capture mode,pre-processing>
Default:
Timed Capture
Options:
0 = Timed Capture
1 = Triggered Capture

Timed Capture

Usage:
Timed Rapid Capture is useful in fast-moving applications in which symbols are only in the field of view for a short time and precise timing is required.
Definition:
In Timed Rapid Capture, decoding occurs independent of and simultaneous with capturing, thus allowing precise timing or no delay at all between captures.
Also, consecutive captures are regarded as the same symbol if the output data is the same.


PreviousNext